LAVA AC/DC Fan Battery Backup Calculator
Calculate estimated battery capacity and backup time for the LAVA 56-inch AC/DC fan. Choose the operating mode: 20W low-voltage or 40W high-voltage. Estimates are for planning; actual results depend on speed, battery condition, temperature, wiring and system losses.
Estimated result
Required nominal battery capacity: —
Estimated energy demand at fan: —
Select your fan mode and enter the required backup time, then calculate.
Formula: Required battery Ah = (Fan watts × hours) ÷ (battery voltage × usable DoD × system efficiency). For 220V AC operation through an inverter, account for inverter efficiency and standby consumption. This calculator uses the system-efficiency input for those losses.
Safety: Confirm battery voltage compatibility, BMS continuous-current rating, fuse/cable sizing and the fan manufacturer’s wiring instructions. Never connect a 12V fan directly to a higher-voltage battery bank.
Frequently Asked Questions
How much power does the LAVA fan use?
It uses 20W in low-voltage mode and 40W in high-voltage mode.
How do I estimate battery backup?
Enter the fan mode, required hours, battery voltage, usable depth of discharge and system efficiency. The calculator estimates the nominal battery Ah required.
Does 220V AC operation need an inverter?
If your available source is DC battery power, an inverter is required for a 220V AC fan input. Include inverter losses and standby consumption in system efficiency.
Is this result a guaranteed backup time?
No. It is an engineering estimate. Actual runtime depends on fan speed, battery age, temperature, wiring, inverter performance and other connected loads.